WireXpert User Interface
© Copyright 2020 Softing IT Networks
27
available with CAT6A+ adapters. Option will be disabled when AC
Wiremap option is enabled.
Note
Crossover can only be selected by selecting a test limit from
Test Settings
Test Limit
Application Standards
. Disabled by default.
Crossover wiremap selections will only be available for the applicable limits as follows:
Straight-
through cable
Crossover at
pairs 12, 36
Crossover at
pairs 12, 36,
54,78
Crossover at
pairs 12, 36
and reversed
at pairs 54, 78
Crossover at
pairs 12, 36
for 2-pair
cable
1000BASE-T
Yes
No
No
Yes
No
1000BASE-TX
Yes
No
Yes
No
No
100BASE-TX
Yes
Yes
Yes
Yes
Yes
10BASE-T
Yes
Yes
Yes
Yes
Yes
User Guide
Refer “User Manual – CAT 6A+ Adapters” for more information.
Lab
Laboratory use only. Password is required to access this section. Please contact your local WireXpert
Vendor for more information.
•
Wiremap Test – If enabled, WireXpert will not continue
with the AUTOTEST process if a wire map FAIL is
detected. Enabled by default.
•
Marginal Pass/Fail –If enabled, WireXpert will display
marginal pass (PASS*) and marginal fail (FAIL*) results.
A marginal test result is obtained when its margin is
smaller than the accuracy specification for the test
parameter. Enabled by default.
•
Save Phase Data – If enabled, WireXpert will generate
information for phase data plot generation. Export
saved results to CSV format using eXport software to
obtain phase data. Impedance plot will be displayed on
eXport. Disabled by default.
•
3/4 dB Rule – If enabled, WireXpert will ignore Return
Loss (RL) measurements if the Insertion Loss (IL) is
<3dB and NEXT measurements if the IL is <4dB.
Disabled by default.
•
Single Ended Test – If enabled, WireXpert will be able
to perform a cable test to obtain only Length & Delay,
RL, NEXT and PS-NEXT results without a REMOTE unit.
Single Ended Test can only be performed using a