Understanding WireXpert
16
© Copyright 2019 Softing IT Networks
3.4.5
Modular Plug Terminated Link (MPTL)
Starting from v7.4, WireXpert has included the MPTL test limits to certify links that features a socket on
the patch panel, and a plug on the opposite side of the link. This is similar to the E2E link, however, is
used when IP-capable devices are permanently installed, e.g, LED lights, building automation elements
or surveillance cameras. The installation cable is plugged directly into the termination deice without the
addition of a socket plus patch cable. A Permanent Link and a Patch Cord test adapter is required to
perform the MPTL test. Press the
[SETUP]
button
Test Settings
Test Limit
TIA
to select the
required MPTL test limit.
The Patch Cord adapter is not part of the standard WireXpert kit. Please contact your local vendor for
more information.
User Guide
Refer “Application Notes - MPTL” for more information.
3.5
Memory
1 Gigabyte internal flash memory.
External USB Flash Drive included allows for flexible data management and storage.
WireXpert only supports FAT/FAT32/exFAT file system.
3.5.1
Memory Requirements
The amount of memory that each test result takes up depends on the options that is configured before
starting the test. If plots are saved with each test, file size of test results will be generally larger than one
that has plots option omitted.
WireXpert allocates approximately 1 GB of internal flash memory for test result storage.
Permanent Link
Test Cord
MODULAR PLUG
TERMINATION
Horizontal Cabling
Horizontal Cabling
with Consolidation Point
MODULAR PLUG
TERMINATION
INTERCONNECT
INTERCONNECT
CP
Fixed Installed Cabling
Correct measurement of MPTL link
Permanent Link Adapter
Patch Cord Adapter