Vega 30 Router User Manual
Power Supply Module Replacement
Maintenance 12.1
Issue1 Revision 1
Page 220
© 2017 SAM
12 Maintenance
12.1 Power Supply Module Replacement
Power supply status is indicated on the Vega 30 front panel. See Section 4.4 “Front Panel
Status Indicators” on page 33. The front status LEDs indicate which Vega 30 Power Supply
Module is faulty.
If the Vega 30 unit is being run with two Power Supply Modules, then replacement of one
Power Supply Module may be done with the Vega 30 powered on.
To replace a Vega 30 Power Supply Module:
1.
Disconnect the Power Supply Module from its AC mains power supply.
2.
Disconnect the Power Supply Module’s DC power cord from the Vega 30 unit.
3.
Connect the replacement Power Supply Module’s DC power cord to the Vega 30 unit.
4.
Connect the Power Supply Module to the AC mains power supply.
5.
Turn on the AC mains supply.
The Power Supply Module has been replaced.
•
Refer to safety information in Section 2 “Safety” on page 8 Section 2 “Safety” on
page 8
•
The installation and maintenance of the Vega 10 Series router(s) and any
associated equipment must be carried out by persons qualified to work with
equipment which may be connected to a mains electric supply.
Note:
Ensure you have a replacement Vega 30 Power Supply Module before starting this
procedure. SAM Order Code: VG30-PSU.