IQUDC30/IQUDC31/IQUDC32/IQUDC33
Operation Using the RollCall Control Panel
Issue 1 Rev 4
Page 40
© 2016 SAM
5.3 Output-Ch1 and Ch2
The Output-Ch1 and Ch2 screens enable you to apply various settings and adjustments to
the video output signal for each video processing channel.
5.3.1 Output Standard
•
Format:
Selects the output format.
•
Default Field Rate:
Selects the output field/frame rate from a choice of Last Valid
Input, 50 Hz, and 60 Hz. This control only has an effect when the channel’s selected
video input is not detected.
Note: The output video field/frame rate will be the same as the selected input to the
channel. If the input is not detected, default field rate allows user control of output
field/frame rate.
•
Current Output Standard:
Shows the output standard currently in use.
Note:
•
The Output-Ch2 screen and SFP Output Routing selection control are only
applicable to the IQUDC31 and IQUDC33.
•
The screen shot above shows the Output Standards available when the Linear
Frame Rate converter option is fitted. When not fitted, only same frame rate
(i.e. format) conversions are permitted.
•
Low frame rate support (i.e. 23, 24, 25, 29 Hz) is not available in modules which
were upgraded to V5.2.7 or above after installation. Only new builds of modules at
version 5.2.7 and above will support low frame rate signals.