Smiths Aerospace
Electronic Systems – Malvern
DOC NO.0134ED
MAINTENANCE MANUAL SUPPLEMENT
BOEING B737-100/200/300/400/500
28-41-04
D. Check that the DCTU Has the Correct Parameters
(1) Push the UP button and the DOWN button at the same time.
(2) The indicator shows the applicable parameter for one second (for example, "P01").
(3) The indicator then shows the value of the applicable parameter.
(4) Make sure the value of the applicable parameter is correct.
(5) Do this procedure for all of the parameters, P01 thru P11.
(a) When you complete the check, the indicator shows the word CAL.
E. Prepare the DCTU for Operation
(1) Set the CAL-RUN jumper on the DCTU to the RUN position.
(2) Move the cover back on the DCTU.
(3) Tighten the screws on the cover.
(4) Install the indicator and the DCTU in the panel.
(5) Tighten the clamp screw.
(6) Push the test switch for the indicators to make sure the indicator operates.
Page 407
Apr 19/02
Airplanes with Smiths 2307 Model Fuel Quantity
Indicators with TSU
EFFECTIVITY