Smiths Aerospace
Electronic Systems – Malvern
DOC NO.0134ED
MAINTENANCE MANUAL SUPPLEMENT
BOEING B737-100/200/300/400/500
28-41-04
FUELING QUANTITY INDICATOR – REMOVAL/INSTALLATION
1. General
A. This procedure has two tasks:
(1) A task to remove the fueling quantity indicator (referred to as the “refuel quantity indicator”).
(2) A task to install the refuel quantity indicator.
2. Refuel Quantity Indicator Removal
A. Access
(1) Location Zone
(a) 402 Right Wing Outboard Leading Edge
(2) Access Panel
(a) 6540 Refueling Station Access Door
B. Procedure
(1) Open these circuit breakers and attach DO-NOT-CLOSE tags:
(a) P6 Main Power Distribution Panel
1) EP GND FUELING
2) FUEL
QTY
(2) Open the access door for the refuel control panel (P15).
(3) Loosen the clamp screw of the applicable indicator.
(4) Remove the indicator from the panel.
(5) Disconnect the electrical connector at the indicator.
3. Refuel Quantity Indicator Installation
A. Access
(1) Location Zone
(a) 402 Right Wing Outboard Leading Edge
(2) Access Panel
(a) 6540 Refueling Station Access Door
B. Procedure
(1) Connect the electrical connector at the indicator.
(2) Install the indicator in the panel.
(3) Tighten the clamp screw on the indicator.
(4) Close the access door for the refuel control panel (P15).
Page 403
Apr 19/02
Airplanes with Smiths 2307 Model Fuel Quantity
Indicators with TSU
EFFECTIVITY