Console Configuration
If you are having difficulties making an out-of-band console
connection to the serial port on the agent module, you can display
or modify the current settings for the serial port through the Web
agent. Click on the serial port icon in the switch image to display
or configure these settings, as shown below.
Speed Status
Indicates the current port speed.
Duplex Status
Indicates the port’s current duplex mode.
Flow Control Status Shows the flow control type in use. Flow control can
eliminate frame loss by “blocking” traffic from end
stations connected directly to the switch.
VLAN
The VLAN ID assigned to untagged frames received
on this port. Use the PVID to assign ports to the same
untagged VLAN.
Parameter
Default
Description
Baud rate
19200 bps
The rate at which data is sent between
devices.
Options : 2400, 4800, 9600, 19200, and auto
detection.
Note that when AUTO is selected, you need
to first press the Enter key once to set the
data rate and initialize the connection.