- 32 -
Initial setting for the ORIG parameters
Refer to the controller’s (LEC series) operation manual for detail.
As the “basic parameter” is unique data of each actuator, if an actuator other than the electric slide table
is used, refer to the operation manual of each actuator and the controller’s (LEC series) operation
manual for the ORIG parameter.
Note1) CCW direction: Extended CW direction: Retracted.
Become effective after restarting the controller.
Note2) Return to origin cannot return while operating / See 5.1
Caution(4) on p.37
<Return to origin>
Before the positioning and pushing operation, “return to origin” is necessary to establish the origin.
The current position value of the electric slide table increases if the table move (move in the CW
direction).
(The default value of CW table moving direction cannot be increased.)
1) Sequence of return to origin
Input the origin signal
→
Move toward origin
→
Stop moving (pushing)
→
Move in the opposite direction
→
Origin
WARNING
Do not alter any parameter except the ones shown. Or else there is a possibility of damage.
Description
(
Extract
)
Initial input value
Input range
ORIG direction
Note1) 2:CCW
1:CW , 2:CCW
ORIG mode
1:ORIG Press
-
LESH**:100
-
ORIG limit
LESH**A:250
ORIG time
100
-
ORIG speed
20
-
ORIG ACC /DEC
100
-
Creep speed
10
-
ORIG sensor
0: Disable
-
Initial set value for
the electric
actuator
Retracted direction
(CCW direction)
Stroke end of
Retracted
direction
Moving distance
1mm
(Not changeable)