Product handling
∗
Mounting
•Do not drop, hit or apply excessive shock to the product.
Otherwise damage to the product can result, causing malfunctions.
•Do not install the product in areas of high humidity or temperature.
Operation outside of the product specification range may cause damage to the product or operation failure or
shorten the product life.
•Connect the product ensuring the direction of "1" (IN) and "2" (OUT) for air direction by following the
arrow indicated on the product.
Incorrect connections may cause malfunction.
•Install with adequate space for maintenance around the product.
Refer to the dimensional drawings for necessary space.
•Tighten the two set screws on the spacer with bracket and spacer evenly.
Tighten them to the recommended tightening torque. Insufficient tightening may cause loosening or sealing
failure, and excessive tightening may cause damage to the screws.
Recommended tightening torque
Unit: N•m
Applicable models
AMS20#
AMS30#
AMS40#
AMS60#
Part No. of spacer with bracket
Y200T-2-D
Y300T-2-D
Y400T-1-D
Y600T-2-D
Part No. of spacer
Y200-D
Y300-D
Y400-D
Y600-D
Tightening torque
0.36±0.036
1.2±0.05
1.2±0.05
2.0±0.1
•When the air combination is fixed on a wall with hexagon socket head cap screws, a hexagonal driver
is recommended as a tool.
•Before piping is connected, the product should be thoroughly blown out with air (flushing) or washed to
remove chips, cutting oil and solid foreign material from inside the piping.
Contamination of piping may cause damage or malfunction.
•When screwing together pipes and fittings, etc., be certain that chips from the pipe threads and sealant
do not get inside the pipe. When a sealant tape is used, leave 1.5 to 2 threads exposed.
•Connect piping/fittings using the recommended torque while holding the female thread side tightly.
Insufficient tightening torque leads to loosening or sealing failure, and excessive tightening leads to damage of the
threads. Tightening without holding the female thread applies an excessive force to the piping bracket directly,
leading to damage.
Recommended tightening torque
Unit: N•m
Thread size
1/8
1/4
3/8
1/2
3/4
1
Tightening torque
3 to 5
8 to 12
15 to 20
20 to 25
28 to 30
36 to 38