-11-
No.PF
※※
-OMA1007
∗
Adjustment and Operation
•Perform settings suitable for the operating conditions. Incorrect setting can cause operation failure.
•Please refer to the PLC manufacturer's manual etc. for details of programming and addresses. For the
PLC protocol and programming refer to the relevant manufacturer's documentation.
•Connect the load before turning the power supply on.
•Do not short-circuit the load.
Although an error is displayed when the product load has a short circuit, the generated over current may lead to
damage to the product.
•Do not press the setting buttons with a sharp pointed object.
This may damage the setting buttons.
•Supply power under no flow conditions.
•If using the product to detect very small flow differences, warm up the product for 10 to 15 minutes
before use.
There will be a drift on the display of approx. 2 to 3% for 10 minutes after the power supply is turned on.
•Perform settings suitable for the operating conditions.
Incorrect setting can cause operation failure.
•During the initial setting, the product will switch the measurement output according to the condition
before setting.
Check the effect on the equipment before setting.
Stop the control system for setting, if necessary.
•Do not touch the LCD during operation.
The display can vary due to static electricity.
∗
Maintenance
•Perform regular maintenance and inspections.
There is a risk of unexpected failure of components due to the malfunction of equipment and machinery.
•Before performing maintenance, turn off the power supply, stop the air supply, exhaust the residual
compressed air in the piping, and verify the release of air.
Otherwise, unintended malfunction of system components can result.
•
Maintenance and checks should be carried out according to the procedure in this operation manual.
Incorrect handling of the product may cause damage or operation failure of the equipment or device.
•Remove the condensate periodically.
If condensate enters the secondary side, it can cause operation failure of pneumatic equipment.
•Do not use solvents such as benzene, thinner etc. to clean the product.
This may damage the surface of the body or erase the markings on the body.
Use a soft cloth to remove stains.
For heavy stains, use a damp cloth that has been soaked with diluted neutral detergent and fully squeezed, then
wipe the stains again with a dry cloth.