-26-
No.PF
※※
-OMA1007
•Connection to Standby regulator
Hub side M12 5-pin A-coded (Socket)
Connector
Pin No.
Signal
Details
1
24 V
24 VDC
2
NC
Not connected
3
0 V
0 V
4
C/Q
ITV: IO-Link
ARS: Output
5
NC
Not connected
Standby E/P regulator (ITV) side M12 5-pin A-coded (Socket)
Connector
Pin No.
Signal
Details
1
24 V
24 VDC
2
NC
Not connected
3
0 V
0 V
4
C/Q
IO-Link
5
NC
Not connected
Standby regulator (ARS) side M12 3-pin A-coded (Socket)
Connector
Pin No.
Signal
Details
3
0 V
0 V
4
C/Q
Output
5
NC
Not connected
•Digital input signal for Standby or Isolation mode
This port is for an input signal to control Standby mode and Isolation mode.
The connection required is according to user's equipment.
M12 5-pin A-corded (Socket)
Connector
Pin No.
Signal
Details
1
24 V
24 VDC
2
IN2
Input for Isolation
3
0 V
0 V
4
IN1
Input for Standby
5
NC
Not connected