Term
Definition
N
Normal condition
The flow which is converted into the volume at 0
o
C and 101.3 kPa (absolute
pressure).
<nor> indicates that the product is in normal condition.
O
Operating fluid temperature
Range of fluid temperature that can be measured by the product.
Operating humidity range
Humidity range in which the product can operate.
Operating temperature range
Ambient temperature range in which the product can operate.
Operation mode
Provide air pressure for the machine to operate.
Output light
A light that turns on when the switch output is ON.
P
Paring
Registration of the PID (Product ID) of the remote to be connected to the base.
Registration occurs at the initial setting, then the wireless system will activate.
Peak value display (mode)
Shows the max. value from when the power was supplied to the current time.
PID
Product ID. A 32 bit digit sequence which is assigned to identify the wireless
unit (base/remote).
PLC
Programmable Logic Controller. A digital computer used for automation of
electromechanical processes.
PNP input
Accepts a sensor output that uses a PNP transistor output signal.
PNP output
The output type that uses a PNP transistor to operate an output device. This is
also known as a negative common type since a negative potential is applied to
the power supply line.
Pressure characteristics
Indicates the change in the display value when the fluid pressure changes.
Pressure ramp up duration
Sets time to reach the setting pressure from isolation mode or standby mode to
operation mode.
Proof pressure
Pressure limit that if exceeded will result in mechanical and/or electrical
damage to the product.
R
Rated flow range
The flow range within which the product will meet all published specifications.
Values outside of this range can be set as long as they are within the set flow
range, but the specifications cannot be guaranteed.
Rated pressure range
The pressure range within which the product will meet all published specifications.
Values outside of this range can be set as long as they are within the set
pressure range, but the specifications cannot be guaranteed.
Rated temperature range
The temperature range within which the product will meet all published
specifications.
Values outside of this range can be set as long as they are within the set
temperature range, but the specifications cannot be guaranteed.
Remote
A unit which establishes wireless communication of input or output data to the base.
Repeatability
Reproducibility of the display value, when the measured quantity is repeatedly
increased and decreased.
R.D.
Current read value
For example, when the display value is 1.000 [MPa], ±5%R.D. is ±5% of 1.000
[MPa], which becomes ±0.05 [MPa]. When the display value is
0.800 [MPa], ±5%R.D. is ±5% of 0.800 [MPa], which becomes ±0.04 [MPa].