-24-
No.PF
※※
-OMA1007
■
Wiring
(1) Power
M12 4-pin A-coded (Plug) connector is used for the connection between the Air
Management Hub and the power supply.
Connector
Pin No.
Signal
Details
1
DC(+)
24 VDC
2
NC
Not connected
3
DC(-)
0 V
4
NC
Not connected
(2) Communication line M12 4-pin D-coded (Socket)
Use this port for Industrial Ethernet communication or access to integrated Web
server.
∗
: type doesn't have the connector.
Connector
Pin No.
Signal
PORT1/PORT2
1
TX+
2
RX+
3
TX-
4
RX-