-63-
No.PF
※※
-OMA1007
•Byte 26 Details
Bit
Description
Details
Value
0
Air Management Hub internal
error 1
L+ short circuit or P24 short circuit
0: No short circuit
1: Short circuited
1
Air Management Hub internal
error 1
Port communication status
0: Device not connected
1: Operate or Pre-operate
2
VP short circuit
VP short circuit detection
0: No short circuit
1: Short circuited
3
Reserved
4
5
6
7
•Byte 27 and 28 Details
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Description
PQ
Dev-Err
Dev-Com
DSStatus
CQ-Short
Pwr-Short
PDmapping-
Mismatch
ID-
Mismatch
Bit
Description
Details
Value
0
ID-Mismatch
Connection device matching error
0: Match
1: Mismatch
1
Pdmapping-Mismatch
Process data mapping size error
0: In size
1: Exceeding size
2
PwrShort
L+ short circuit or P24 short circuit
0: No short circuit
1: Short circuited
3
CQShort
C/Q short circuit
0: No short circuit
1: Short circuited
4
DSStatus
Data storage (DS) save status
0: DS saved data error, no DS data
1: DS saved data is valid
5
DevCom
Port communication status
0: Device not connected
1: Operate or Pre-operate
6
DevErr
Event status (Device or master
event status)
0: No event or notification
1: Warning or Error
7
PQ
Received input process data Valid
(normal)/invalid (abnormal)
0: Invalid (abnormal)
1: Valid (normal)