Other Settings
○Reset operation
The Accumulated Flow, Peak Value, and Bottom Value can be reset.
To reset the accumulated value, press the DOWN and SET buttons simultaneously for 1 second or longer.
Resetting the accumulated flow is possible only when the accumulated flow is displayed.
Resetting the peak value and bottom value is effective for the measurement target displayed in the peak
display or bottom display.
○Display select function
The number of accumulated flow rate display digits can be temporarily switched when the temperature and
accumulated flow rate are set in the measurement display settings.
The normal accumulated display consists of the mantissa part (maximum 6 digits) and [Power value
display] indicated by the index part displayed by x10
6
or x10
3
.
If the DOWN button is pressed for 1 second, the mantissa part will be displayed in 9 digits and the power
value will be displayed as x10
3
.
∗
: If there is no button operation for 30 seconds while the 9-digit power is displayed, the number of displayed powers will return to
6 digits.
∗
: When the temperature is set to "hide", the displayed power value is fixed at 9 digits.
○Zero-clear function
When the pressure is displayed in the measurement display setting, the displayed value can be adjusted to
zero within the range of ±7%F.S. from the factory default value.
(The zero clear range varies by ±1% F.S. due to variation between individual products.
When the UP and DOWN buttons are pressed simultaneously for 1 second or longer in measurement
mode, the image below is displayed and the displayed value is reset to zero.
The display returns to measurement mode automatically.