SECTION 4, Page 4
SJ-600 Series Engine Powered
112715
June 2001
ELECTRICAL SYSTEM
TROUBLESHOOTING INFORMATION
CHOKE INOPERATIVE
FROM PLATFORM OR
ENGINE CONTROLS
(Dual Fuel)
ENGINE CRANKS BUT
WILL NOT START
(Continued)
16. Loose or broken wire #11 from fuel
valve (2G11) to fuel pump (FP1).
17. Defective fuel pump (FP1) (Gasoline
Only).
18. Open diode (D57) from starter motor
to ignition coil.
19. Choke inoperative (Dual Fuel).
20. Defective glow plugs (Diesel).
21. No spark (Dual Fuel).
1. Engine oil lever low.
2. Engine overheated.
3. Defective temperature switch (TPS1).
4. Defective oil pressure switch (OPS1).
5. Loose or broken wire #2B from oil
pressure switch (OPS1) to
temperature switch (TPS1).
6. Loose or broken wire #2A from relay
(10BCR2) to oil pressure switch
(OPS1).
7. Loose or broken wire #10B from base
terminal block to relay (10BCR2).
8. Loose or broken wire #10A from base
terminal block to relay (10BCR2).
9. Loose or broken wire #37 from relay
(10BCR2) to ignition coil (Dual fuel).
or diesel valve solenoid (2D37)
(Diesel).
10. Defective relay (10BCR2).
1. Loose or broken wire #31A from
choke switch (S31) to choke solenoid
(CS31A).
2. Defective choke solenoid (CS31A).
1. Loose or broken wire #10 from key
select switch (S3) to choke switch
(S13).
2. Defective choke switch (S13).
3. Loose or broken wire #31 from choke
switch (S13) to choke relay (31CR).
4. Loose or broken wire #02 from relay
(31CR) to base terminal block (TB1).
5. Loose or broken wire #05 from base
terminal block (TB1) to relay (31CR).
6. Loose or broken wire #31A from relay
(31CR) to base terminal block (TB1).
7. Loose or broken wire #31A from base
terminal block (TB1) to choke
solenoid (CS31A).
8. Defective choke relay (31CR).
16. Check continuity. Replace if
defective.
17. Check pump. Replace if defective.
18. Check diode. Repair if necessary.
19. Check choke. Repair if necessary.
20. Check glow plugs. Repair if
necessary.
21. Refer to engine manufacturer
service manual.
1. Refill to proper level.
2. Check cooling system.
3. Check switch. Replace if defective.
4. Check switch. Replace if defective.
5. Check continuity. Replace if
defective.
6. Check continuity. Replace if
defective.
7. Check continuity. Replace if
defective.
8. Check continuity. Replace if
defective.
9. Check continuity. Replace if
defective.
10. Check relay. Replace if defective.
1. Check continuity. Replace if
defective.
2. Check solenoid. Replace if
defective.
1. Check continuity. Replace if
defective.
2. Check switch. Replace if defective.
3. Check continuity. Replace if
defective.
4. Check continuity. Replace if
defective.
5. Check continuity. Replace if
defective.
6. Check continuity. Replace if
defective.
7. Check continuity. Replace if
defective.
8. Check relay. Replace if defective.
ENGINE STARTS BUT
WILL NOT CONTINUE
RUNNING
TROUBLE
PROBABLE CAUSE
REMEDY
CHOKE INOPERATIVE
FROM PLATFORM
(Dual Fuel)
Summary of Contents for SJ-7027