General Operation
For problems with the cabinet and refrigeration unit use the following table.
Refer to relevant section in this service manual for safe access to perform
repair.
Problem
Possible Cause
Repair
• Cabinet not operating
• No controller display
• Loss of power supply
• Check mains power
supply.
• Loose plug
• Check all plugs are
connected correctly.
• Excess noise vibration
• Refrigeration pipes
transferring vibration into
cartridge
• Re-align pipes away from
other parts.
• Frozen evaporator coil
• Set-point is too cold
• Check and raise.
• Evaporator probe fault
• Check and replace
evaporator probe.
• Controller fault
• Replace controller.
• Short of refrigerant
• Perform refrigeration
system diagnostics and
service as required.
• Power consumption is
higher than expected
• Refrigeration unit
operating too hot
• Clean the condenser.
• Ensure the cabinet has
good ventilation around
the refrigeration unit
• Ensure the cabinet is
within the maximum
operating temperature.
• Cabinet door is opened
excessively
• Ensure door is closed
more often.
• Set point too low
• Raise set point
Continued over page