Installation
Service Manual
6
Installation
Installation Guidelines
When installing this cabinet, ensure the installation guidelines below are
considered and met.
Ventilation Requirements
This cabinet must have the following ventilation clearances at all times:
*When installed for continuous duty in climate class 7 environment (35°C
ambient / 75% relative humidity), it is recommended to provide 50 mm
clearance around the sides and back of the cabinet.
Ventilation
Ensure all ventilation
requirements below are
met.
Door Opening
Allow adequate space
for the door/s to open
and close properly.
Sunlight
Do not install the
cabinet in direct
sunlight.
Uneven Surface
Do not install the cabinet
on an uneven surface.
Surface
The installation surface
must be capable of
supporting the loaded
cabinet.
Power Supply
Do not overload the power
supply.
Blocking
Ventilation
Do not store boxes or items
in front or on top of the
cabinet.
Climate Class
The cabinet must be
installed in an
environment within its
climate class.
The climate class is stated
on the cabinet rating label
inside the cabinet.
No below clearance required
Min.
100mm
left side
Keep area in front of
grille and drawers clear
Chef Base Cabinets
No behind
clearance
required
*
No below clearance required
Min.
100mm
left side
Keep area in front of
grille and drawers clear
Chef Base Cabinets
No behind
clearance
required
*