26
Troubleshooting and Diagnostics
Service Manual
SKOPE ReFlex Chef Base Fridge
• Product is too warm.
• Frequent door opening.
• Limit door openings.
• Recently loaded
• Allow time for the product
to cool down.
• Door not closing properly. • Check and clean door
gasket.
• Refrigeration unit
operating too hot.
• Excessive door opening
or refrigeration heat load.
• Ensure the cabinet has
good ventilation around
the refrigeration unit.
• Ensure the cabinet is
within the maximum
operating conditions.
• Set point is too high
• Lower set point.
• Moisture build up on door
or exterior.
• High humidity.
• Check ambient operating
temperature and
ventilation requirements,
and reposition cabinet if
necessary.
• Frequent door opening.
• Limit door openings.
• Door not closing properly. • Check and clean door
gasket.
• Cabinet door does not
shut properly.
• Cabinet is on an uneven
surface.
• Level the cabinet.
• Door is obstructed.
• Check shelves and
product.
• Warm cabinet
temperatures
• Compressor operating for
long periods (more than 1
hour)
• Blocked condenser
• Clean the condenser.
• Poor ventilation around
the refrigeration unit
• Ensure the cabinet has
good ventilation around
the refrigeration unit.
• Ensure the cabinet is
within the maximum
operating temperature.