background image

SKOPE Contacts

SKOPE Industries Limited

A.B.N. 73 374 418 306
AU: 1800 121 535
NZ: 0800 947 5673
[email protected]

www.skope.com

Summary of Contents for ReFlex Chef Base

Page 1: ...ReFlex Chef Base SKOPE Chef Base Fridge Hydrocarbon Service Manual MAN80308 Rev 1 0 Oct 2021...

Page 2: ...demark Infringement The SKOPE trademark on this product is infringed if the owner for the time being does any of the following Applies the trade mark to the product after their state condition get up...

Page 3: ...otes 17 4 Wiring ReFlex Chef Base Fridge 18 5 Spare Parts Chef Base 4 Drawer Assembly 20 Parts ReFlex Chef Base 21 Integrated Unit Components 22 Parts Integrated Unit 22 6 Installation Installation Gu...

Page 4: ...cal Connections 32 Cartridge Electrics Panel 33 Condenser Fan 34 Evaporator Fan 36 Compressor 38 Electronic Controller 39 Controller Location 39 QC Terminals 39 Replacing the Controller 40 Control Pro...

Page 5: ...are Flammable refrigerant Venting of hydrocarbon and compressor oil Asphyxiation Do not interfere with the refrigeration system All refrigeration maintenance and repairs must be undertaken according t...

Page 6: ...ickly isolate power supply to cabinet x MUST NotperformanyHotWork brazingetc inthefield Thesearetobecompletedinasuitable service depot workshop in a dedicated specific Hazardous Work Area compliant to...

Page 7: ...cable to the SKOPE ReFlex Chef Base Fridge models detailed in the table below Refer to the relevant product specification sheet available on the SKOPE website www skope com for specifications Model SK...

Page 8: ...e SKOPE also recommend that all technicians have the Wellington Drive Track app installed See SCS Connect Field App and Track App on page 11 for information on setting up and using the app SCS Connect...

Page 9: ...ture or messages The temperature is what the sensor inside the cabinet detects and not necessarily the product temperature However they may be very close depending on how the controller is set to sens...

Page 10: ...settings are suspected reload the complete parameter set Reset Returns the controller back to factory settings Parameter set must be reloaded after performing a reset Manual test Allows inspection of...

Page 11: ...Enter your unique Activation Code and press Activate The activation code is provided by SKOPE Customer Services 3 Enter a 4 digit PIN code re enter the code and press SET PIN CODE 1 Ensure Bluetooth i...

Page 12: ...recorded on warranty job card It is not recommended that parameters are changed unless absolutely necessary If incorrect parameter settings are suspected reload the complete parameter set Note Update...

Page 13: ...DISCONNECT has been selected from the menu after loading new parameter set Statistics Information from the past seven days on cabinet activity including temperatures door openings and alarms SCS info...

Page 14: ...t self closing torsion fault door switch circuit controller Excessive door open counts Over voltage protection The maximum allowable mains supply voltage has been exceeded The cabinet has temporarily...

Page 15: ...ent damage This alarm may occur due to very high ambient temperature 2 3 4 cabinet installed in location outside rated conditions condenser not clean poor installation ventilation condenser fan motor...

Page 16: ...self closing gasket leaking product hot blocking cabinet airflow overloaded from excess door openings ambient fan motor blade condenser evaporator controller compressor gas leak remove cabinet 29 Com...

Page 17: ...17 SKOPE ReFlex Chef Base Fridge Electronic Controller Service Manual Notes...

Page 18: ...g Service Manual SKOPE ReFlex Chef Base Fridge 4 Wiring ReFlex Chef Base Fridge WIRE COLOURS BK Black BN Brown RD Red OG Orange GN Green BU Blue GY Grey WH White GNYE Green Yellow Based upon IEC 757 S...

Page 19: ...Black 3 way Black 3 way S6 P6 Light Unit Socket Plug White 3 way White 3 way S7 P7 Unit to Controller Power Socket Plug 1 Red 4 way Orange 4 way S8 P8 Door Sensor Socket Plug White 2 way White 2 way S...

Page 20: ...20 Spare Parts Service Manual SKOPE ReFlex Chef Base Fridge 5 Spare Parts Chef Base 4 Drawer Assembly 13 25 3 19 18 20 21 1 2 7 4 14 16 22 12 17 5 24 23 15 6 8 8 10 11...

Page 21: ...CK RAIL KN SSY12429 LEFT BACK RAIL KN SSY12393L 10 WIRING BOX U BENCH KN ELZ12383 11 DRAWER COMPONENT LH LOCK KN SSY12431R 12 DRAWER COMPONENT RH LOCK KN SSY12400R 13 AIR DUCT KN SSY12432 14 GUIDE KN...

Page 22: ...4D 1 CONDENSER SHIELD KN SSY12435 2 CONDENSER COIL KN CLS12391 3 CONDENSER TRAY KN ELZ12384 4 CONDENSATE LINE KN FIL12387 5 FILTER DRIER KN DRY12386 6 CONDENSER FAN BLADE KN COT12385 7 COMPRESSOR KN...

Page 23: ...and close properly Sunlight Do not install the cabinet in direct sunlight Uneven Surface Do not install the cabinet on an uneven surface Surface The installation surface must be capable of supporting...

Page 24: ...as If required the cabinet exterior can be cleaned as instructed in the cleaning section of this service manual see Routine Cleaning on page 44 Drawers Where fitted drawers should be removed for clean...

Page 25: ...display Loss of power supply Check mains power supply Loose plug Check all plugs are connected correctly Excess noise vibration Refrigeration pipes transferring vibration into cartridge Re align pipe...

Page 26: ...ower set point Moisture build up on door or exterior High humidity Check ambient operating temperature and ventilation requirements and reposition cabinet if necessary Frequent door opening Limit door...

Page 27: ...ing the side panels The evaporator can only be removed by safely degassing the entire unit detaching the entire benchtop and cutting or detaching the suction line A frost back check can be completed b...

Page 28: ...clips into the drawer frame and runs around the perimeter of the drawer Remove the gasket by peeling it from the door frame starting at a corner If the gasket is out of shape after refitting use a hai...

Page 29: ...stors To fit the height adjustable legs Unit End Panel The panel at the LH end of the cabinet can be replaced To replace the end panel 1 Raise the cabinet off the ground and unbolt the castors from th...

Page 30: ...f a sealed system fault is suspected the system must not be opened it must be sent to a SKOPE approved service depot for repair Safety hazards The main hydrocarbon safety hazards are Flammable refrige...

Page 31: ...zone 1 5m around the cabinet Refrigeration gauge set suitable for R290 flammable refrigerant Service vehicle Suitable for transporting flammable gas being HC refrigeration systems Vehicle storage area...

Page 32: ...YS ensure reconnection has been undertaken correctly as operational faults may occur if incorrect UNPLUG Door switch White Ambient probe White Condenser probe Orange Evaporator probe Blue Control prob...

Page 33: ...connectors for the integrated cartridge and cabinet Due to the confined space within the electrics box plugs may come loose as a result of movement and vibrations during servicing Take care when refi...

Page 34: ...ended torque settings To access and remove the condenser fan assembly IMPORTANT Replace the motor with the same SKOPE OEM part DO NOT use alternative parts Fan motor manufacturer Torque setting Wellin...

Page 35: ...ssembly to the cartridge Following the same path as the original probe secure the condenser fan motor cable with cable ties as necessary 5 Reassemble and test 1 Remove the condenser fan assembly and t...

Page 36: ...fan assembly is fixed to evaporator shroud with screws and metal bars It is important that the assembly is replaced with the same part to ensure safety correct alignment and refrigeration performance...

Page 37: ...ase Fridge Replacement Procedures Service Manual 3 Unscrew the duct mounting screws and remove the duct 4 Unscrew all the evaporator fan shroud mounting screws 5 The evaporator assembly can be removed...

Page 38: ...ions and ensure the compressor electrics are operating correctly The compressor must be supplied with consistent voltage over 220 volts ensure the voltage does not drop at start up If the voltage does...

Page 39: ...tion The electronic controller is located on the electrics panel at the front of the refrigeration cartridge To access and remove the controller QC Terminals The terminals at the back of the controlle...

Page 40: ...form electrical safety test and reconnect to the power supply 5 Use a mobile device to connect to the controller with the SCS Connect Field app see SCS Connect Field App and Track App on page 11 6 Nav...

Page 41: ...place the evaporator fan assembly on page 36 2 Take note of cable routing photo recommended then carefully cut cable ties to release the probe cable Detach the probe from the evaporator assembly trace...

Page 42: ...tor and unplug 3 Replace the probe Following the same path as the original probe fit the new probe with cable ties as necessary Ensure the probe is located in the same location between the 4th and 5th...

Page 43: ...abinet from the power supply remove the unit cover and remove the LH panel see Unit End Panel on page 29 2 Take note of cable routing photo recommended then carefully cut cable ties to release the pro...

Page 44: ...s as shown Reverse operation to refit drawers to cabinet after cleaning see Drawers on page 24 Cabinet Ensure the cabinet is unplugged from the power supply before cleaning Wipe the outside of the cab...

Page 45: ...net from the power supply 2 The filter is located behind the unit bottom grille Rotate the grille out and slide the filter up and off the cabinet 3 Clean the filter with a vacuum cleaner wash with col...

Page 46: ...SKOPE Contacts SKOPE Industries Limited A B N 73 374 418 306 AU 1800 121 535 NZ 0800 947 5673 skope skope com www skope com...

Reviews: