Replacement Procedures
Service Manual
Ambient Probe
The ambient probe is located in front of the condenser coil. It monitors the
temperature around the refrigeration unit.
Note:
The ambient probe is wired
in series with the door switch.
To replace the ambient probe
1. Disconnect the cabinet from the power supply, remove the unit cover and
remove the LH panel
(see “Unit End Panel” on page 29).
2. Take note of cable routing (photo recommended), then carefully cut cable
ties to release the probe cable. Detach the probe from the front of the
cartridge, and trace the probe cable back to its connector and unplug.
3. Following the same path as the original probe, run the new probe to the
condenser coil and secure with cable ties. Locate the probe in the same
location as the original probe.
4. Reassemble and test.