42
Replacement Procedures
Service Manual
SKOPE ReFlex Chef Base Fridge
Evaporator
Probe
The evaporator probe is located within the evaporator coil. It controls the
refrigeration system defrost initiation and termination.
To replace the evaporator probe
Condenser
Probe
The condenser probe is located on the side of the condenser coil.
To replace the condenser probe
1. Gain access to the evaporator fan assembly (see steps 1-2, “To access and
replace the evaporator fan assembly” on page 36).
2. Take note of cable routing (photo recommended), then carefully cut cable
ties to release the probe cable. Carefully separate the coil fins around the
probe, withdraw the probe from the evaporator coil, trace back to its
connector and unplug.
3. Replace the probe. Following the same path as the original probe, fit the
new probe with cable ties as necessary.
Ensure the probe is located in the same location (between the 4th and 5th
fins), secured in place with the evaporator fins, and that the probe cable is
securely connected and cable tied in place.
4. Reassemble and test for correct operation.
1. Disconnect the cabinet from the power supply and remove the left hand end
plate “Unit End Panel” on page 29
2. Take note of cable routing (photo recommended), then carefully cut cable
ties to release the probe cable. Detach the probe from the side of the
condenser coil, and trace the probe cable back to its connector, and unplug.
3. Following the same path as the original probe, run the new probe to the
condenser coil and secure with cable ties. Locate the probe in the same
location as the original probe.
4. Reassemble and test for correct operation.