51
SKOPE OD400
‐
2
Replacement Procedures
Service Manual
Compressor
The compressor is located at the front of the refrigeration unit behind the
compressor cover.
Before replacing the compressor, ensure the compressor electrics are
operating correctly and that the compressor is being supplied with
consistent voltage over 220 Volts. Ensure the voltage does not drop at start-
up. If the voltage does drop, ensure the unit has a direct power supply (not
from a multi-box or extension cord).
To access the compressor
Compressor
Electrics
The compressor electrics box is fixed onto the side of the compressor.
To access the compressor electrics
1. Remove the front kick panel and isolate the chiller from the power supply
(see page 42).
2. Remove the refrigeration unit (see page 49).
3. Remove the condenser cover (see step 3 on page 50).
4. Remove the compressor cover from the refrigeration unit by unscrewing the
fixing screws and lifting the cover off.
Compressor (compressor
cover removed)
Compressor electrics
1. Gain access to the compressor (see steps above).
2. Use a flat head screwdriver to ease the electrics cover from the electrics box.