43
SKOPE OD400
‐
2
Replacement Procedures
Service Manual
Lighting
The chiller is fitted with two LED side lights powered by a 24V 25W LED
driver power supply.
The cabinet interior lights will switch on when the cabinet is plugged in, and
will stay on permanently while the cabinet is connected to the power supply.
LED modular lighting components are all non-serviceable items. If a
component is faulty, it should be removed and a new replacement
component fitted. Before replacing a lighting component, determine the part
number, and replace with the same type.
Note:
Fluorescent tubes cannot be
used in place of LED light modules.
Refer to the diagnostics table below to determine what component may be
at fault, and the procedures over the next few pages for component
replacement instructions. Ensure the cabinet is isolated from the power
supply before cleaning or removing parts.
Modular lighting fault diagnostics
Interior Lights
The interior lights are located on either side of the cabinet front opening.
Follow the steps below to replace an interior light.
To replace an interior light
LED Driver
Power Supply
The 24V 25W LED driver power supply is located on the electrics plate
assembly. Refer to page 44 for information on accessing the LED driver
power supply.
Problem
Possible Cause
Repair
No lights working.
Cabinet is dark.
Plug not connected
properly.
Check cabinet light
supply plug on side of
refrigeration unit.
LED driver power supply
fault.
Replace LED driver
power supply.
Modular light component
not working.
Plug not connected
properly.
Check and clean plug
connection.
Faulty modular lighting
component.
Replace faulty modular
lighting component.
Segment of modular
component not working.
Faulty modular lighting
component.
Replace faulty modular
lighting component.
1. Remove the front panel and isolate the chiller from the mains power supply
2. Remove the light diffuser by squeezing it until it is released from the housing.
3. Unclip and unplug the LED light module from the cabinet.
4. Fit the new LED light module.
5. Perform electrical safety Reassemble and reconnect the chiller to the power
supply.