Electronic Controller
Service Manual
SKOPE OD400
‐
2
Program 405 - CAREL ir33 (ELZ3333)
Continued over page
Revision No.
1.0
Controller Code
BN1
Setting
Units
Access
Description of Parameter
Level
Min
Max
Password Parameter (PS) =
66
Probe Parameters
/2
4
-
C
1
15
/3
4
-
C
0
15
/6
0
-
C
0
1
/A2
2
-
C
0
5
/A3
3
-
C
0
5
/c1
-4
°C
C
-20°C
20°C
Control Parameters
St
2
°C
F
r1
r2
rd
1
°C
C
0.1°C
20°C
r1
0
°C
C
-50°C
r2
r2
4
°C
C
r1
200°C
r4
0
°C
C
-20°C
20°C
r5
1
-
C
0
1
rt
0
Hours
F
0
999
rH
0
°C
F
-
-
rL
0
°C
F
-
-
Compressor Parameters
c0
1
Mins
C
0
15
c2
3
Mins
C
0
15
c3
10
Mins
C
0
15
c4
10
Mins
C
0
100
Defrost Parameters
dI
2
Hours
C
0
250
dt1
4
°C
C
-50
200
dtn
6.5
°C
C
-50
200
dP1
60
Minutes
C
1
250
d6
1
-
C
0
2
dd
0
Minutes
C
0
15
d8
0
Hours
C
0
15
d/1
0
°C
C
-
-
d10
10
Minutes
C
0
250
d11
-9
°C
C
-50°C
20°C
Alarm Parameters
A0
2
°C
C
0°C
20°C
AL
-5
°C
C
-50°C
200°C
AH
13
°C
C
-50°C
200°C
Ad
120
Minutes
C
0
250
A5
7
-
C
0
15
Ac
60
°C
C
0.0°C
200°C
AE
10
°C
C
0.1°C
20°C
Fan Parameters
F1
5
°C
C
-50°C
200°C
F2
1
-
C
0
1
F3
1
-
C
0
1
Fd
1
Minutes
C
0
15
Fon
2
Minutes
C
0
15
FoF
2
Minutes
C
0
15
Configuration Parameters
H0
1
-
C
0
207
H2
1
-
C
1
6
H4
0
-
C
0
1
H5
3
-
C
0
15
H6
0
-
C
0
255
H17
0
-
C
0
1
H18
0
-
C
0
1
H19
0
-
C
0
1
H21
0
-
C
0
1
H22
1
-
F
0
1
H23
0
x10 Mins
F
0
250
HACCP Parameters
HAn
0
-
C
0
15
HA.y_ _
0
Year
C
0
99
HA.Π_ _
0
Month
C
1
12
HA.d_ _
0
Day
C
1
31
HA.h_ _
0
Hour
C
0
23
HA.n_ _
0
Minute
C
0
59
HA.t_ _
0
Hours
C
0
99
High Temperature HACCP Alarm - Year of most recent event
Night mode setback timeout (X 10min increments)
High Temperature HACCP Alarm - Number of Events Recorded
Enable Real Time Clock (RTC)
Enable RTC Alarm
Aux button assigned to Light or Aux output (0= Light output, 1 = Aux Output)
Power Saving Mode (0 = MAX Power Save. 1 = Std Power Save)
High Temperature HACCP Alarm - Month of most recent event
High Temperature HACCP Alarm - Day of most recent event
High Temperature HACCP Alarm - Hour of most recent event
High Temperature HACCP Alarm - Minute of most recent event
High Temperature HACCP Alarm - Duration of most recent event
Disable 'Quick View Inputs' Keypad Function (0=Enabled, 1=Disabled)
Configuration relay AUX2 (R3)
Buttons to lock when keypad locked
Serial address
Keypad and IR Remote Control Functions (1 = All functions Enabled)
Disable buzzer (0=enabled, 1 = disabled)
Evap Fan On Time (when F0 or F0n = 4 or 5)
Evap Fan Off Time (when F0 or F0n = 4 or 5)
Evap Fans Start Temperature
Evap Fans Off When Compressor Off
Evap Fans During Defrost & Dripping (0 = Fans ON, 1 = Fans OFF)
Evap Fans Off Time After Dripping
Condenser Alarm Shutdown Set Point
Cond. Warning (Divided by 2 - i.e. 10 = 5K diff from Ac)
Configuration of digital input 2
High Temperature Alarm threshold (see A1 for absol. or rel. to Sp)
Low and high temperature alarm delay
Alarm and fan differential
Low Temperature Alarm threshold (see A1 for absol. or rel. to Sp)
Compressor Running Time Defrost; Run Time
Compressor Running Time Defrost; Evaporator Temp. Threshold
Bypass alarms after defrost
Display Evap 1 probe temp (Read only)
Display during defrost (0= dF (flash), 1 = temperature at start of defrost, 2 = dEF)
Dripping time after defrost
End Defrost Temperature in night mode
Maximum defrost duration
Interval between defrosts (if not using real time clock)
End defrost temperature, (if d0 = 0 or 1)
Minimum compressor OFF time
Minimum compressor ON time
Comp ON time if Control Probe Fails (OFF Time = 15mins)
Temperature Set Point
Comp. and fan start delay at power up
Enable monitoring (NOT related to HACCP)
Elapsed monitoring time (Read only)
Max temperature during period rt (Read only)
Min temperature during period rt (Read only)
Minimum Set Point allowed
Maximum Set Point allowed
Value to alter Set Point by when in Night mode
9 July 2015
Display
Range
Measurement stability
Probe display speed
Disable Decimal Point (0 = decimal point displayed)
Probe 2 configuration (0=probe absent, 2=evap, 3=cond)
Differential
Probe 3 configuration (0=digital input, 2=evap, 3=cond)
Calibration of probe 1
405
Electronic Controller Parameter Sheet
BN1
Available parameter sets for this program:
Perishable Mode
CPS1008-405-BN1
ELZ3333AP-405
Last revised on
SKOPE ir33 Custom Controller
IRSKC0HF325 Rev 0.343
Controller Type
Application
OD400-2
SKOPE Part Number