56
Replacement Procedures
Service Manual
SKOPE OD400
‐
2
Condenser Probe
The condenser probe determines refrigeration shutdown due to overheating
of condensing temperature. The condenser probe is located and insulated
on outside middle tube of condenser.
To access the condenser probe
1. Remove the front kick panel and isolate the chiller from the power supply
2. Remove the refrigeration unit (see page 49).
3. Remove the compressor cover.
4. The condenser probe is now accessible. The condenser probe is fitted to the
side of the condenser coil.
Compressor
Condenser probe
Condenser coil