Electronic Controller
Service Manual
Evaporator Probe
The evaporator probe measures the evaporator coil temperature and stops
the defrost cycle once the evaporator coil reaches a set temperature.
Temperature Probe Reading
The temperature of each of the three temperature probes can be displayed
by pressing and holding both the
and
keys simultaneously for 5
seconds.
To display the temperature probe readings
Temperature probe readings
1. Press and hold both
the
and
keys simultaneously
for 5 seconds.
2. Press and hold the
key to scroll the
probes (see table below). The
key
is not active for this function. This
function will time out after 60 seconds
(cannot be turned off prior to 60
seconds elapsed time).
Display
Description
P_1
Control probe temperature
P_2
Evaporator probe temperature
P_3
Condenser probe temperature
P_4
Unused
P_5
Unused