background image

ATTENTION

This IceMaster is designed to manage your 
fermentations by cooling water/glycol to 
a set temperature in a reservoir which will 
then be circulated via a submersible pump 
through your specific cooling coils/jacket/
plate/system.

Freezing can occur so icing in the reservoir 

is considered normal operation. To 

compensate for this we recommend that 

one uses a 20% propylene glycol solution 

to lower the freezing point. 

Unpack your unit and open the top cover to find the 
power cord, drain plug, and temperature probes. 
Install the drain plug and place the power cord aside 
for now.

Plug in the temperature probes to all pump controllers 
and attach 3/8" tubing to form a return loop on all sets 
of inlets and outlets.

Open the top cover and fill the reservoir with tap water.

Plug in the power cord and flip the red switch to power 
on the unit.

Set the temperature for each controller at the front of 
the unit to 2°C.

• Hold the ‘Up’ button for 3 seconds until the 

number is flashing. The flashing number is your set 
temperature.

• While the number is flashing, press the ‘Down’ 

button to decrease the set temperature or press the 
‘Up’ button to increase the set temperature.

• Once you have adjusted the set temperature, wait 

for the number to stop flashing and the controller 
will return to normal operation mode and display 
the temperature probe reading.

The pumps should now kick on and begin recirculating 
water through the return loops. Look for water flow 
and confirm each pump is operating correctly and 
check for leaks around your connections.

TIP

 -

 If you plan to use a propylene glycol 

 If you plan to use a propylene glycol 

solution with the IceMaster, unthread the drain 

solution with the IceMaster, unthread the drain 

plug to drain the tap water used for testing.  

plug to drain the tap water used for testing.  

If you will be using water only, be sure to keep 

If you will be using water only, be sure to keep 
the reservoir temperature set at or above 2°C 

the reservoir temperature set at or above 2°C 

to avoid freezing.

to avoid freezing.

Icemaster Reservoir

At the back of the unit, adjust the reservoir 
controller to 2°C.

• Hold the ‘S’ button until F1 is displayed.

• Press ‘S’ again, which will enter the temperature 

adjustment mode.

• Then hold ‘S’ and the up or down button 

simultaneously to alter the set temperature of 
the reservoir.

Once you have confirmed that the reservoir is 
cooling, the pumps are operating, and you have 
no leaks, you are finished with the initial assembly 
and testing and can move onto to setting up the 
unit with your cooling system.

Assembly And Testing Instructions

ICEMASTER MAX 4

Thank you for purchasing the IceMaster refrigeration 

unit. You are taking a big step to better manage 

fermentation temperatures, and ultimately making 

cleaner, more consistent beverages.

1

2

3

4

5

6

7

8