6. Assembly
- 77 -
951-180-083-EN
Version 02
WARNING
Follow ATEX guidelines when con-
necting the equipotential bonding
cable!
PE cable provided by customer
24-3820-
XX
XX
-A
TEX
6.6 Establishing equipotential bonding
-See Figure 33
The product has an equipotential bonding
connection (screw M6).
The product and its equipotential bonding
connection must be connected to the equi-
potential bonding of the main machine.
WARNING
Explosion protection
The cross-section of the standard
grounding cable to be supplied by the
customer must be at least 2 mm
2
.
• Loosen the clamping screw (
2
) on the
ground terminal (
1
)
• Insert the cable end of the standard
grounding cable (
3
) into the ground
terminal
• Tighten the clamping screw (
2
)
• Perform PE continuity test
Equipotential bonding connection (screw M6)
1
3
2
Fig. 33
Equipotential bonding