1. Safety instructions
Residual risk
Possible in
lifecycle
Avoidance / Remedy
Generation of electrostatic charges or sparks by
dropping of parts
C, D, E, F, G
Secure parts against falling. if necessary, cover parts to avoid sparking.
Introduction of catalytic, unstable, or pyro-
phoric substances into the potentially explosive
atmosphere
C, D, E, F, G
Ensure that none of these substances enter the potentially explosive atmosphere; have
all substances approved by the operator in advance
Use of isolating amplifiers, for example to oper-
ate a capacity sensor in the potentially explosive
atmosphere
C, D, G
Install isolating amplifiers only outside of the potentially explosive atmosphere
Use of an unsuitable lubricant for low tempera-
tures; at low temperatures, excessive lubricant
viscosity can cause loss of pump function
C, D
Use only lubricants suitable for the specific operating temperature in each case
Lifecycles: A = Transport, B = Assembly, C = First start-up, D = Operation, E = Cleaning, F = Maintenance, G = Malfunction, repair,
H = Shutdown, K = Disposal