11
EN
11. Faults
10
- 89 -
951-180-083-EN
Version 02
11.
Malfunctions, causes, and remedies
Fig. 40 Malfunctions table 1
Fault
Possible cause
Remedy
Insufficient lubricant
discharge
Air cushion in main metering device or secondary metering device
Perform venting on the secondary metering device discharg-
ing too little lubricant.
Grease progressive system - see Chapter 7.1
Oil progressive system - see Chapter 7.2
No lubricant at lubri-
cation points
Main metering device or secondary metering device is defective
- Can be detected if no grease can be pressed through the metering
device after removing all union nuts or fittings at the outlets.
Replace the metering device
- Loosen all fittings, mark lines, secure against outside
influences
Install a new metering device
Notice!
The metering and arrangement of sections on the new
metering device must be identical to the previous (defective)
metering device.
Install lubrication lines in the correct order as marked
previously
Only use original SKF spare parts!
Perform start-up and functional inspection
Check the flow in the main metering device and secondary metering
device
- Sequentially remove union nuts or fittings at the outlets; check
valves may be built into the outlet fittings.
- Trigger intermediate lubrication.
- The metering device is functioning properly if significant grease dis-
charge is seen at all outlets.
- Replace the metering device if grease does not discharge at all
outlets.
Defective or blocked secondary feed line
Detach feed line, identify cause of blockage, replace second-
ary feed line if necessary
Summary of Contents for LINCOLN VP Series
Page 115: ...115 951 180 083 EN Version 02 Notes...
Page 117: ......