EN
6. Assembly
- 62 -
951-180-083-EN
Version 02
6.4.2 VPK tightening torques
NOTICE
Inlet and outlet fittings - see Chapter 14.2.
VPK dimensions
Thread connection
VPKM
Inlet:
M10x1
Outlet:
M10×1
VPKG
G1/8"
G1/8"
Type
Number of
progressive
metering
device
sections
Number
of possible
outlets
L1
L2
Weight
[mm]
[mm]
[kg]
VPKM-3 / VPKG-3
1)
3
6
68.4
79.9
0.99
VPKM-4 / VPKG-4
4
8
84.6
96.1
1.18
VPKM-5 / VPKG-5
5
10
100.8
112.3
1.38
VPKM-6 / VPKG-6
6
12
117.0
128.5
1.57
VPKM-7 / VPKG-7
7
14
133.2
144.7
1.77
VPKM-8 / VPKG-8
8
16
149.4
160.9
1.96
VPKM-9 / VPKG-9
9
18
165.6
177.1
2.16
VPKM-10/VPKG-10
10
20
181.8
193.3
2.35
1) This progressive metering device must be installed with check valves.
The specified torques must be observed during
assembly and repair.
Tie-rod (starter plate)
(M8)
2.4 Nm ± 0.1 Nm
Nut for tie-rod
(M8)
12 Nm ± 1.0 Nm
Inlet and outlet fittings
Type of fitting
Sealing with O-ring
10 Nm ± 1.0 Nm
Sealing with EOlastic ring
10 Nm ± 0.1 Nm
Sealing with copper or alu-
minum ring
15 Nm ± 1.5 Nm
Sealing by
sealing edge,
with Loctite 243
15Nm ± 1.5 Nm
Sealing with
Conical nipple
1
)
15Nm ± 1.5 Nm
Plug screw M6x10
10Nm+1 Nm
1) Minimum of 9 Nm at drying time of
> 1h sufficient
Summary of Contents for LINCOLN VP Series
Page 115: ...115 951 180 083 EN Version 02 Notes...
Page 117: ......