![SKF LINCOLN VP Series Operating Instructions Manual Download Page 56](http://html1.mh-extra.com/html/skf/lincoln-vp-series/lincoln-vp-series_operating-instructions-manual_1287102056.webp)
EN
6. Assembly
- 56 -
951-180-083-EN
Version 02
Fig. 15 VP progressive metering device with 3/2 directional solenoid valve
HM
BM
LM
ø7
24 24
17
20
35
156.3
6.5
57
L1 ±2
L2 ±2
max.5
10.5
72
98
(für VPG und VPM)
G1/4
39
SW5
SW13
G1/4
B
A
C
Fig. 14 VP progressive metering device with
2/2 directional solenoid valve
HM
BM
LM
ø7
24
24
17
20
35
156
6.5
57
L1 ±2
L2 ±2
max.5
10.5
72
89
6
(für VPG und VPM)
G1/4
SW13
SW5
B
A
6.3.5 VP progressive metering device with 2/2 directional
solenoid valve
6.3.6 VP progressive metering device with 3/2 directional solenoid
valve
Minimum mounting dimensions
BM = Width:
130 mm
HM = Height:
185 mm
LM
= Length:
L2+110 mm
Minimum mounting dimensions
BM = Width:
130 mm
HM = Height:
185 mm
LM
= Length:
L2+110 mm
Seat valve, double-
sided blocking,
de-energized C
connected to B, A
blocked
Seat valve, double-
sided blocking, de-
energized closed
Summary of Contents for LINCOLN VP Series