3. Overview, functional description
3.5 Overview of VPK progressive metering device series
The VPK sectional progressive metering de-
vice is available in the designs VPKM (met-
ric threaded connectors) and VPKG (inch
threaded connectors). With their metering
sections, VPKM and VPKG cover a nominal
volume per outlet and cycle of 0.05 cm
3
(twin section) to 0.6 cm
3
(single section).
The inlet of the metering device is located
at an inlet section. The outlets are at the
downstream metering device sections. The
delivery ducts are sealed by elastic seals
(plates). An end section is located down-
stream of the last metering device section.
All sections are interconnected with tie-rods.
They seal the metering device assembly.
The volumetric flow fed via a tube is forcibly
distributed in a predetermined ratio to the
outlets, i.e., to the lubrication points or the
downstream progressive metering devices.
Pistons aligned in series meter the lubricant
for two opposite outlets each and control the
function of the neighboring piston. This way,
the function of the sectional metering device
can be checked by monitoring any piston by
1 2 3
4 5
Legend
1
VPK basic design for oil and grease, without attachments, without monitoring
2
VPK basic design with cycle indicator for oil or grease, monitoring type ZY (visual
monitoring)
3
VPK with inductive NAMUR sensor for oil or grease, monitoring type ZS (electric
monitoring)
4
VPK with 2/2 directional solenoid valve for oil and grease, attachment 13
5
VPK with 3/2 directional solenoid valve for oil and grease, attachment 14
Fig. 6
VPK progressive metering device series