4.3 VPB volume data for metering device outlets
4.3.1
Basic design of VPB progressive metering device
Volume data for VPB metering device outlets, Table 11
Max. inlet volumetric flow 400cm
3
/min
Nominal volume
Minimum volume
1
)
(at maximum stroke)
(at compulsory stroke, design value
only under difficult conditions)
Volume per cycle and
outlet
Volume per cycle and outlet
[cm
3
]
[cm
3
]
0.20
0.13
1) See explanation in Chapter 3.3, Information on volume data.
Progressive metering device VPB, basic design, Table 12
VPB Basic design with terminal for equipotential bonding
Type
hydraulically controlled
Mounting position
Any
Ambient temperature range
-25 to + 110 °C
- with cycle indicator
-20 to + 70 °C
Inlet and outlet threads
VPBM (metric thread)
M10x1
VPBG (inch thread)
G1/8
Material
Steel, galvanized, optional stainless
Hydraulic
Operating pressure max.:
Oil 200 bar, grease 300 bar
Volume per outlet and cycle
See Table 11
Lubricant
Mineral oils, greases based on mineral oil,
environmentally friendly and synthetic oils
and greases
Operating viscosity
> 12 mm
2
/s
Worked penetration
≥ 265 x 0.1 mm (up to NLGI Grade 2)