6. Assembly
- 73 -
951-180-083-EN
Version 02
Fig. 29 VPB progressive metering device with
3/2 directional solenoid valve
Fig. 28 VPB progressive metering device
with 2/2 directional solenoid valve
6.5.5 VPB progressive metering device with 2/2 directional
solenoid valve
6.5.6 VPB progressive metering device with 3/2 directional sole-
noid valve
6.5.7 Assembly of the VPB progressive metering device
Minimum mounting dimensions
BM = Width:
100 mm
HM = Height:
180 mm
LM
= Length:
L+60 mm
HM
BM
LM
820-
XX
XX
-A
TEX
17
15
32
153
5
60
~54
20
20
60
0
7
G1/8
24-3820-XXXX
19
B
A
Minimum mounting dimensions
BM = Width:
100 mm
HM = Height:
180 mm
LM
= Length:
L+60 mm
HM
BM
LM
B
A
C
G1/8
G1/8
17
15
32
153
20
33
5
60
~54
20
20
60
24-3820-XXXX
29
0
7
Seat valve, double-
sided blocking,
de-energized C
connected to B, A
blocked
Seat valve, double-
sided blocking, de-
energized closed