6. Installation
- 54 -
951-171-021
Version 02
6.7 Lubrication line connection
CAUTION
Risk of falling
Exercise care when dealing with lu-
bricants. Bind and remove spilled or
leaked lubricants immediately.
Connect lubrication lines in such
way that no forces are trans-
ferred to the product (tension-
free connection).
All components of the centralized lubrication
system must be laid out for:
○
the maximum arising operating pressure
○
the admissible ambient temperature
○
the output volume and the lubricant to be
supplied
○
The lubricant flow should not be impeded
by the installation of sharp elbows, angle
valves, gaskets protruding to the inside,
or cross-section changes (big to small).
Provide unavoidable changes of the cross
sections in the lubrication lines with as
smooth transitions as possible
Observe the following installation instruc-
tions for safe and smooth operation.
○
Use clean components and filled lubrica-
tion lines only
○
The main lubrication line should be laid
preferably rising with a possibility to vent
it at its highest point. Lubrication lines
shall generally be laid in such way that
there can never be created air pockets at
any point
○
Possibly mount the lubricant metering
devices at the end of the main lubrication
line in such way that the outlets of the lu-
bricant metering devices show upwards
○
If lubricant metering devices have to be
mounted below the main lubrication line,
then this should not be done at the end of
the main lubrication line