1. Safety instructions
1.24 Initial commissioning / daily start-up
Ensure that:
○
All safety devices are completely available
and functional
○
All connections are correctly connected
○
All parts are correctly installed
○
All warning labels on the product are
present completely, highly visible and
undamaged
○
Illegible or missing warning labels are to
be replaced without delay
○
All components used must be designed
according to the maximum operating
pressure and the maximum respectively
minimum ambient temperature
○
No parts of the centralized lubrication
system may be subjected to torsion,
shear, or bending
○
Check all parts prior to their usage for
contamination and clean, if necessary
○
Lubricant lines must be primed with
lubricant prior to installation. This makes
the subsequent ventilation of the system
easier
○
Observe the specified tightening torques.
When tightening, use a calibrated torque
wrench,
○
When working with heavy parts use suit-
able lifting tools
○
Avoid mixing up or wrong assembly
of dismantled parts. Mark these parts
accordingly
1.25 Cleaning
○
Risk of fire and explosion when using
inflammable cleaning agents Only use
non-flammable cleaning agents suitable
for the purpose
○
Do not use aggressive cleaning agents
○
Thoroughly remove residues of cleaning
agents from the product
○
Do not use steam jet and high pressure
cleaners. Electrical components may be
damaged. Observe the type of protection
of the pump
○
Cleaning work may not be carried out on
energized components
○
Mark damp areas accordingly