EN
4. Technical data
4
- 47 -
951-180-076-EN
Version 0y
Type code structure
F B
1 5
F
1 M 0 6
B
0 4 1 0 1 0
B
D
4 1 2 8
A G
x x
(A)
(B)
(C)
(D)
(E)
(F)
(G) (H) (K)
(L) (M)
(N)
(O)
(P)
Important equipment features of the
product can be identified based on the
type code. The type code is on the
product's rating plate.
Order example:
For a unit of type FB with a 15 kg reservoir
(15), with fill level control,
2 switching points min., max. (F), drive type
1M (1M) with a drive speed 06 (105:1) (06),
drive position B (B), 4 pump elements with
piston Ø 6 mm (04), 10 pump elements with
piston Ø 8 mm (10), 10 pump elements with
piston Ø 10 mm (10), tube connection B with
Ø 8mm (B), modification letter D (D), ATEX
design key 4128,
II 2G c IIc T4 Gb (4128), motor values (1M) for
rated speed 1000 rpm, 50 Hz, rated power of
0.25 KW, rated voltage of 230/400 V (AG),
ATEX motor protection class (see rating plate
for motor), the order number is: Order
number:
FB 15 F 1M 06 B 04 10 10 B D 4128 AG xx
4.2.4 FB type code
(A)
Product designation
FB
Number of pump elements
from:
to:
(B)
Reservoir design's
nominal volume
(G)
Piston diameter 6 mm
00
= 0
24
= 24
06
= 6 kg /
15
= 15 kg
(H)
Piston diameter 8 mm
00
= 0
24
= 24
30
= 30 kg
(K)
Piston diameter 10 mm
00
= 0
24
= 24
(C)
Type of fill level monitoring
(L)
Connection for pump elements
Fom gmease:
A
pipe
Ø 6 mm
G
=vis. fill level control (dip stick)
B
pipe
Ø 8 mm
E
= fill level control, 1 switching point (min.)
C
pipe
Ø 10 mm
F
= fill level switch, 2 switching points (min., max.)
D
Ø 1/4 NPT female thread
H
= fill level control, 3 switching points (min., min.
pre-warning, max.)
(M)
Modification letter/version number
D
J
= fill level control, 4 switching points (min., min.
pre-warning, max. pre-warning, max.)
(N)
ATEX design key
Fom oil:
4128
II 2G c IIC T4 Gb
S
= Vis. fill level control (sight glass)
4130
II 2D c IIIC T125°C Db
W
= Reed contact, 1 switching point (min.)
(D)
Drive type
1M
= Motor drive with double gear reduction
(O)
Motor data
2M
= Motor drive with single gear reduction
Depending on the technical data from the respective
motor manufacturer - see order confirmation
(E)
Drive speed
(P)
ATEX motor protection class
1M
=
06
= 105:1 /=
07
= 288:1 /
08
= 720:1
- See mating plate (motom)
2M =
04
= 45:1
(F)
Motor drive position
See Chapter 6.3. 1 to Chapter 6.3.5
1M
A / B
or
E / G
(E / G only for 6 and 15 kg reservoirs)
2M
H
∑ ≤ 24