Simrad SP60
48
851-164574 / C
Display unit
The display unit should be located so that it is best protected from
glare which reduces readability. It may be:
•
Panel mounted
•
Desktop mounted
•
Bulkhead mounted
•
Overhead mounted
Refer to the display unit’s instruction manual for the compass safe
distance.
Sonar Operating Panel
An ergonomiclly correct Operating Panel helps to reduce operator
fatigue. It should be mounted in a nearly horizontal position to
facilitate trackball operation, and within easy viewing range of the
display unit.
The compass safe distance must be allowed for when planning the
unit’s location:
•
Standard compass 0.05 m.
•
Steering compass 0.05 m.
Sonar Processor Unit
The Sonar Processor Unit (MC70) should be installed inside a
console, in a cabinet or on a desk. Make sure that adequate
ventilation is available to avoid overheating.
The compass safe distance must be allowed for when planning the
unit’s location:
•
Standard compass 0.15 m.
•
Steering Compass 0.1 m.
Sonar Interface Unit
The Sonar Interface Unit should be mounted vertically with the
cable inlet downwords on a side wall inside a console, cabinet or
desk. Provide enough space for easy access for cable connections
to the unit.
The compass safe distance must be allowed for when planning the
Sonar Interface Unit’s location:
•
Standard compass TBD m.
•
Steering Compass TBD m.