Technical specifications
163
851-164574 / C
FS3300 Trawl system
The serial output of the FS3300 system sends a 2-byte binary depth
value. With a measurement in units of 0.1525879 m, the data
format is:
Osbbbbbb bbbbbbbb
where (from left towards right):
Component
Content
O
Indicates valid output when set
s
Sign bit
b...b
14--bit absolute depth value in units of 0.1525879
m.