Simrad SP60
178
851-164574 / C
C15 - Transceiver Unit interface
This is the main interconnection cable between the Sonar Interface
Unit and the Transceiver Unit in the sonar room. The connection
to the Sonar Interface Unit is made with the pre-fitted 25-pin Delta
connector, which connects to
J3
. The connection to the
Transceiver Unit is made on terminal block
E201
.
W208D / Rev.A
Sonar Interface Unit - Transceiver Unit
1
31
47
35
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
15
27
43
2
29
45
16
25
41
4
23
39
18
19
35
5
21
37
19
17
33
7
15
21
11
8
13
22
9
10
7
11
5
24
3
25
1
1R - 24 Vdc s)
1R
1BL
2R
2BL
3R
3BL
4R
4BL
5BL
6BL
7BL
8BL
5R
6R
7R
8R
1BL - 24 Vdc standby (-)
2R - Hoist
2BL - Lower
3R - Upper limit switch
3BL - Lower limit switch
4R - Rotation sensor
4BL - PU ground
5R - On/Off
5BL - -24 Vdc standby
6R - Audio (+)
6BL - Audio (-)
7R - Cheapernet (+)
7BL - Cheapernet (-)
8R - Reset (+)
8BL - Reset (-)
Transceiver Unit
E201
Sonar Interface Unit
J3
The cable is provided by the manufacturer.
Summary of Contents for SP60 - REV D
Page 2: ......
Page 14: ...Simrad SP60 X 851 164574 C Notes...
Page 61: ...Transceiver unit 45 851 164574 C Figure 13 Mounting the Transceiver Unit CD3110A...
Page 214: ...Notes...
Page 215: ...Notes...
Page 217: ......