Testing the peripheral equipment
125
851-164574 / C
10.2 General
Default interface settings
The sensor settings are all preset to these recommended
connections.
Sensor
Type
Port
Baudrate
Talker
Trawl system
ITI
6
4800
None
FS
6
4800
None
Echo sounder
NMEA
5
4800
None
Purse seine system
PI30
6
4800
None
Position system
GPS
4
4800
None
Speed log
SpeedLog
9
9600
SS
Heading
Gyro
3
4800
None
Hull unit
Stabilization
Weather
Wind
4800
None
Changing the interface settings
To change any of the interface settings, observe the following
procedure.
1
Select the
Setup
menu.
2
Press the
Test...
button to open the
System Test
menu.
3
Press the
Installation Menu
button.
4
Observe the
Installation menu
appear on the top of the
display.
5
Select
I/O Setup
on the
Installation menu
, and then
Sensors
.
6
Observe a submenu listing all the available sensors.
7
Move the cursor down on the submenu, but do not press the
Select
button on the Operating Panel.
8
Observe that each sensor has a new submenu listing the
default choices or
None
. The chosen setting is marked.
9
Select
None
if you wish to disable the sensor input.
10
Select any of the other settings if you wish to define the
sensor interface parameters.
11
Observe the
Sensor Config
submenu appear at the bottom
of the menu field.
12
Make the appropriate settings for the sensor.