28
007-4377-002
2: System Control
Command Targeting
All commands entered affect only the local brick. You can target a command to all bricks
(including the local brick) by prefixing the command with an asterisk (
*
).
001c05-L1> * version
001c05:
L1 0.7.37 (Image A), Built 11/24/2004 14:59:42 [2MB image]
004i01:
L1 0.7.37 (Image A), Built 11/24/2004 14:59:42 [2MB image]
002c01:
L1 0.7.37 (Image A), Built 11/24/2004 14:59:42 [2MB image]
001x01:
L1 0.7.37 (Image A), Built 11/24/2004 14:59:42 [2MB image]
001c05-L1>
Viewing Information, Warnings, and Error Messages
All information, warnings, and error messages generated by any of the system
controllers are in the following form:
001c05 ERROR: invalid arguments for ‘ver’ command, try “help ver”
The general format of the message includes a brick identification (this is not present if the
command was to the local brick only), type of message, and the message. These messages
can be the result of an invalid command (as shown in the example) or from tasks running
on the L1, such as the environmental monitor.
Each L1 has a log of local events. Use the L1 command
log
to view the event on any of
the L1s.
Summary of Contents for SGI Altix 3700 Bx2
Page 1: ...SGI Altix 3700 Bx2 User s Guide Document Number 007 4377 002 ...
Page 4: ......
Page 12: ......
Page 16: ......
Page 70: ...46 007 4377 002 3 System Overview Figure 3 1 SGI Altix 3700 Bx2 Series Systems ...
Page 85: ...Tall Rack 40U 007 4377 002 61 Figure 4 1 Tall 40U Rack ...
Page 88: ......
Page 90: ...66 007 4377 002 5 CR brick Figure 5 1 Front and Side View of CR brick ...
Page 128: ......
Page 136: ......
Page 144: ......
Page 184: ......