128
007-4377-002
11: D-brick2 Storage Module
Powering the D-brick2 On or Off
This section explains how to power the D-brick2 on and off.
Powering On the D-brick2
Before powering on the D-brick2, confirm that the following is true:
•
Drives are seated in the correct bays and blank plates are fitted in any empty bays.
•
Ambient temperature is within the specified range of 10 ˚C to 40 ˚C (50 ˚F to 104 ˚F).
•
The system power distribution unit (PDU) and power distribution strip (PDS) are
on.
To power on the D-brick2, follow these steps:
1.
Connect an AC power cord to each PSU/cooling module.
2. Connect the AC power cords to the system PDS.
3. Turn the power switch on each PSU/cooling module to the “on” position (I = on,
O = off). See Figure 11-4 on page 126 for switch locations.
The green “PSU good” LED illuminates. Also, the “power on” LED on the ESI/ops panel
(see Figure 11-4 on page 126) of each module turns green when AC power is present.
If the “power on” LED on the ESI/ops panel does not illuminate, or if the amber
“system/ESI fault” LED illuminates, verify that you followed all steps. For
troubleshooting tips, see the
SGI Total Performance 9100 (2Gb TP9100) Storage System
User’s Guide
or contact your service provider.
Summary of Contents for SGI Altix 3700 Bx2
Page 1: ...SGI Altix 3700 Bx2 User s Guide Document Number 007 4377 002 ...
Page 4: ......
Page 12: ......
Page 16: ......
Page 70: ...46 007 4377 002 3 System Overview Figure 3 1 SGI Altix 3700 Bx2 Series Systems ...
Page 85: ...Tall Rack 40U 007 4377 002 61 Figure 4 1 Tall 40U Rack ...
Page 88: ......
Page 90: ...66 007 4377 002 5 CR brick Figure 5 1 Front and Side View of CR brick ...
Page 128: ......
Page 136: ......
Page 144: ......
Page 184: ......