8
007-4377-002
1: Operation Procedures
2. If you want to power on the bricks connected to the CR-brick, enter the following
command:
oo3c01-L1> * power up
(* indicates all)
3. From the L1 prompt, display the brick configuration information by entering the
following command:
001c05-L1> config
In L1 mode, you can obtain only limited information about the system
configuration. A CR-brick only has information about its attached I/O brick and, if
another CR-brick is attached to the I/O brick, information about that CR-brick and
its attached I/O brick. An I/O brick only has information about its attached
CR-brick and an R-brick only has information about itself.
The L1 controller display, located on the front of each brick, should display
L1 running
once the power-on procedure starts.
Powering Off the System
You can power off individual bricks or your entire server system using either the system
console interface or the L1 controller of the primary CR-brick.