D-brick2 External Components
007-4377-002
125
A key (Torx screwdriver) to lock or unlock the disk drives is provided with each
D-brick2. A red indicator is visible in the center rectangular aperture in the handle if the
anti-tamper lock is locked, and a black indicator is visible when the lock is unlocked (see
Figure 11-3).
Figure 11-3
Anti-Tamper Locking on the D-brick2 Disk Drive
Power Supply/Cooling Modules
Two power supply/cooling modules (PSUs) are mounted in the rear of the D-brick2.
These modules supply redundant cooling and power to the enclosure and are
auto-ranging. The supplies should be plugged into your SGI rack’s power distribution
strip (PDS). Four LEDs mounted on the rear panel of the D-brick2’s PSU/cooling module
indicate the status of the power supply and the fans (see Figure 11-4 on page 126).
Note:
If a power supply fails, do not remove it from the enclosure until you have a
replacement power supply. The cooling fans in the supply will continue to operate.
Caution:
You must finish replacing a PSU/cooling module within 10 minutes after
removing one. Otherwise, thermal overload of the D-brick2 can result.
Anti-tamper lock
Unlocked
Indicator
aperature
Locked
!
Summary of Contents for SGI Altix 3700 Bx2
Page 1: ...SGI Altix 3700 Bx2 User s Guide Document Number 007 4377 002 ...
Page 4: ......
Page 12: ......
Page 16: ......
Page 70: ...46 007 4377 002 3 System Overview Figure 3 1 SGI Altix 3700 Bx2 Series Systems ...
Page 85: ...Tall Rack 40U 007 4377 002 61 Figure 4 1 Tall 40U Rack ...
Page 88: ......
Page 90: ...66 007 4377 002 5 CR brick Figure 5 1 Front and Side View of CR brick ...
Page 128: ......
Page 136: ......
Page 144: ......
Page 184: ......