Powering the D-brick2 On or Off
007-4377-002
129
Powering Off the D-brick2
Before powering off the D-brick2, confirm that the following has occurred:
•
All system users have been notified and are logged off.
•
Disk data has been backed up as appropriate.
To power off a D-brick2 enclosure, follow these steps:
1.
Move the power switch on the rear of each PSU/cooling module to the “off”
position (position
I
= on,
O
= off). See Figure 11-4 on page 126 for switch locations.
2. Unplug the power cable from the PSU/cooling module(s) as appropriate. For
example, you would follow this step if you are replacing an individual module.
3. If you are shutting down multiple bricks in the system, you may want to switch the
PDS or PDU breaker switch to the “off” position.
The LEDs on the back of the unit should turn dark a few seconds after you power off the
PSU/cooling module.