7: PX-brick
Rear Panel Components
The PX-brick has the following rear panel components (see Figure 7-4):
•
Power switch.
Moving the power switch to the
1
position powers on the L1
controller of the PX-brick, and moving it to the
0
position powers off the L1
controller. The 12-VDC LED illuminates green when the L1 controller is powered
on.
•
12-VDC LED.
The 12-VDC LED illuminates green when the L1 controller is
powered on and operating. The L1 controller is powered on by turning on the
power switch.
•
48-VDC LED.
The power switch must be in the ON (
1
) position for this LED to
illuminate. The 48-VDC LED illuminates green when the rest of the PX-brick
internal components are powered on and operating. The rest of the internal
components are powered on by pressing the On/Off switch on the front panel of
the brick, or via the L2 controller display or system console.
•
PWR (power) connector.
This connector connects to a power bay, which provides
power to the PX-brick.
•
PCI/PCI-X slots.
These slots support PCI or PCI-X cards. See “Adding or Replacing
a PCI or PCI-X Card” on page 136. The card slots are numbered bus 1 through bus 6.
Each bus has two slots, labeled 1 and 2, as shown in Figure 5-4.
•
PCI-X Slot LEDs.
Each slot has the following LEDs:
–
PWR (power) LED.
This LED illuminates green when the PCI card carrier is
installed securely and is getting power.
–
Fault LED.
This LED illuminates yellow when a fault occurs with the PCI card.
•
XIO 10 and XIO 11 connectors.
Each connector can connect the PX-brick to one
compute brick (CR-brick). As an option, the second connector can be connected to
another compute brick to create a dual-ported PX-brick, which would provide
greater bandwidth.
•
XIO 10 and XIO 11 connector LEDs.
Each connector has two LEDs, as follows:
–
The yellow LED illuminates to indicate that both the PX-brick and the compute
brick to which it is connected are powered on.
–
The green LED illuminates when a link has been established between the
PX-brick and the brick to which it connects.
Summary of Contents for SGI Altix 3700 Bx2
Page 1: ...SGI Altix 3700 Bx2 User s Guide Document Number 007 4377 002 ...
Page 4: ......
Page 12: ......
Page 16: ......
Page 70: ...46 007 4377 002 3 System Overview Figure 3 1 SGI Altix 3700 Bx2 Series Systems ...
Page 85: ...Tall Rack 40U 007 4377 002 61 Figure 4 1 Tall 40U Rack ...
Page 88: ......
Page 90: ...66 007 4377 002 5 CR brick Figure 5 1 Front and Side View of CR brick ...
Page 128: ......
Page 136: ......
Page 144: ......
Page 184: ......