Console Hardware Requirements
The console type and how these console types are connected to the Altix 3700 Bx2 servers
is determined by what console option is chosen.
If you have an Altix 3700 Bx2 server with a dumb terminal, you can connect the terminal
via a serial cable to the (DB-9) console port connector on the rear of the CR-brick.
The terminal must be set to the following functional modes:
•
Baud rate of 38,400
•
8 data bits
•
One stop bit, no parity
•
Hardware flow control (RTS/CTS)
You can also connect a USB-to-Ethernet adapter to the CR-brick or R-brick and place it
on a network. This starts an L2-level emulator on the brick’s system controller. Use the
telnet
command to connect to the CR-brick or R-brick.
Table 2-2 provides information on connection points for the USB-to-Ethernet adapter
depending on the system size.
Table 2-2
Location Guidelines for Connecting USB/Ethernet Adapters
System Size
Rack Number
Brick Type
Slot Number (U-Location)
64 Processor
or smaller
001
CR
Bottom CR-brick in rack
128 Processor 001
R-brick
U-23
256 Processor 002
003
R-brick
R-brick
U-17
U-23
512 Processor 003
003
009
009
R-brick
R-brick
R-brick
R-brick
U-05
U-35
U-05
U-35
Summary of Contents for SGI Altix 3700 Bx2
Page 1: ...SGI Altix 3700 Bx2 User s Guide Document Number 007 4377 002 ...
Page 4: ......
Page 12: ......
Page 16: ......
Page 70: ...46 007 4377 002 3 System Overview Figure 3 1 SGI Altix 3700 Bx2 Series Systems ...
Page 85: ...Tall Rack 40U 007 4377 002 61 Figure 4 1 Tall 40U Rack ...
Page 88: ......
Page 90: ...66 007 4377 002 5 CR brick Figure 5 1 Front and Side View of CR brick ...
Page 128: ......
Page 136: ......
Page 144: ......
Page 184: ......